Product Consultation
Your email address will not be published. Required fields are marked *
MID Din Rail Type Single Phase Multi-function Energy Meter for EV Charging Metering
Jul 26,2022
CT Type RS485 Modbus Single Phase Din Rail Energy Meter for PV Metering
May 30,2025
MID/ UL Approved Single Phase Din Rail Type Multi-function Energy Meter for EV Charging Metering
Nov 24,2022
CT Connection Single Phase Din Rail Wifi Energy Meter for PV Metering
May 30,2025
RCM 40mA CT Input Din Rail Single Phase Multi-function Solar PV /Zero Export Meter for PV Metering
Nov 24,2022
Din Rail Dual Channels DC Energy Monitoring Meter for EV Charging Metering
Aug 02,2022Content

Modern electrical installations require more than a simple kilowatt-hour counter. Building operators, solar installers, electric vehicle charging providers, industrial users, and utility contractors increasingly need compact meters that can measure energy, display essential electrical values, communicate with supervisory systems, and operate reliably in demanding environments. A single-phase meter must therefore combine measurement accuracy, installation convenience, communication capability, safety, and long service life in one practical device.
The SDM120-M is designed for this purpose. It is a single-phase, two-wire, multifunction energy meter with direct current measurement up to 45 A. Installed on a DIN rail, it occupies only one 18 mm module, making it suitable for compact distribution boards, residential control panels, small commercial installations, photovoltaic systems, and equipment monitoring applications. Its functions extend beyond active energy measurement to include voltage, current, active power, reactive power, apparent power, power factor, frequency, demand-related values, and bidirectional energy.
With an LCD featuring backlighting, two pulse outputs, and an RS485 communication interface supporting Modbus RTU, the meter provides both local visibility and remote data access. Depending on the selected model version, communication and output options can also support M-Bus or related utility communication requirements. This flexibility allows users to select a configuration that matches the architecture of the installation without changing the basic compact meter platform.
The product is manufactured by Eastron Electronic Co., Ltd., a specialist developer and producer of electricity meters, power analyzers, current sensors, communication modules, and energy management solutions. The company combines product development, embedded electronics expertise, laboratory testing, manufacturing control, and international technical support to provide measurement products for a broad range of markets.

RS485 Modbus/DLT645 Din Rail Single Phase Multi-function Energy Meter
The meter is intended for RMS measurement on a single-phase AC system configured as 1P2W, or one phase and neutral. It is rated for a nominal voltage of 230 V and supports an operational voltage range from 85 to 276 V AC. The direct current path accepts a rated current of 5 A and a maximum current of 45 A, allowing the device to monitor many small loads without the cost, wiring complexity, and additional space associated with an external current transformer.
Direct connection is one of the product’s most important practical benefits. In small installations, adding a current transformer can create several disadvantages. The installer must select a suitable transformer ratio, provide additional wiring, allocate panel space, and verify correct polarity and burden requirements. A direct-connected meter reduces these steps. It can be wired directly into the current circuit, which helps simplify commissioning and reduces the number of components that could be incorrectly installed.
The 45 A maximum direct-load capability makes the device appropriate for many residential and light-commercial circuits. Typical examples include apartment distribution boards, individual consumer circuits, small heat pumps, lighting systems, domestic equipment, auxiliary building services, small workshops, and individual charging or generation branches. The exact suitability of an installation must always be confirmed against local electrical regulations, protective-device ratings, conductor sizes, and the meter’s installation instructions.
The meter measures both imported and exported active energy. This bidirectional capability is particularly useful where electricity can flow in both directions, such as in a solar photovoltaic installation with grid interaction. Instead of treating all energy as consumption, the meter can distinguish between energy received from the supply and energy delivered back to the supply, provided that the system configuration and communications software are set up correctly.
A conventional energy meter generally presents one principal value: accumulated kilowatt-hours. That information is useful, but it does not explain why energy consumption is changing or whether the electrical system is operating efficiently. The multifunction design adds operational context by measuring a group of instantaneous and accumulated electrical parameters.
Measured values include voltage, current, active power, reactive power, apparent power, power factor, frequency, and active and reactive energy. The device also supports demand-related information such as maximum demand, depending on the selected display page and configuration. These values help users identify abnormal loading, voltage instability, poor power factor, unexpected standby consumption, and changes in operating behavior.
Voltage measurement helps verify whether the monitored circuit is operating within an expected range. A consistently low or high voltage reading may indicate supply problems, excessive voltage drop, loose connections, or an installation issue. Current measurement shows the actual electrical load and can help identify overload risks or equipment that is drawing more current than expected.
Active power represents the power being converted into useful work, heat, light, or mechanical output. Reactive power is associated with the energy exchanged by inductive and capacitive loads. Apparent power combines the active and reactive components and is useful when evaluating the loading of electrical infrastructure. Power factor indicates how effectively current is being converted into useful active power. Together, these values provide a much more complete picture than energy accumulation alone.
Frequency measurement is valuable for checking the stability of the AC supply and for identifying unusual operating conditions. In a normal grid-connected system, frequency is expected to remain close to its nominal value. Monitoring frequency can be helpful in backup power systems, generators, microgrids, and applications where supply quality is important.
Because the meter presents these parameters locally through its LCD and remotely through communication, the same device can serve both maintenance personnel and energy management software. A technician can inspect readings at the panel, while a building management system can collect data automatically for dashboards, alarms, reports, or cost allocation.
Measurement accuracy is a central consideration when selecting an energy meter. The published specifications provide accuracy values of ±0.5% for voltage and current, ±0.2% for frequency, ±1% for power factor, and ±1% for active, reactive, and apparent power. Active energy accuracy is specified as Class 0.5/1 under IEC 62053-21 and Class C/B under EN 50470-3:2022. Reactive energy is specified as Class 2 under IEC 62053-23.
These classifications indicate that the meter is intended for applications where energy data must be dependable for monitoring, allocation, operational analysis, and selected regulated or semi-regulated applications. Accuracy is not only determined by the electronic measurement circuit. It also depends on installation quality, conductor arrangement, operating temperature, load level, wiring polarity, supply conditions, and correct configuration.
For this reason, the device should be installed according to the relevant technical documentation and local standards. Connections must be tightened correctly, the phase and neutral conductors must be correctly identified, and the circuit must be protected by suitable upstream equipment. If the meter is being used for billing, tenant allocation, or another legally controlled purpose, the user should verify the required approval, verification, sealing, and installation procedures in the applicable jurisdiction.
The product information identifies MID approval as one of its strengths. MID, or the Measuring Instruments Directive framework, is relevant to certain European measurement applications. Approval status can vary according to the exact product version, marking, certificate, and intended use, so purchasers should confirm that the supplied model has the approvals required for their project. The combination of declared accuracy classes and approval capability gives system designers a stronger basis for selecting the device for professional metering projects.
The maximum 45 A direct connection is a clear advantage in applications where the monitored load falls within the meter’s direct-measurement range. External current transformers are useful for high-current systems, but they add cost and engineering requirements. A compact direct-connected meter is often more economical for individual circuits and small feeders.
Direct connection can also simplify the bill of materials. Instead of purchasing a meter, current transformer, mounting accessories, secondary wiring, and possibly shorting terminals, the installer can use a single compact meter with appropriately sized conductors and protective equipment. Fewer components can mean fewer opportunities for polarity errors, ratio mismatches, loose secondary connections, and incorrect programming.
The rated current is listed as 5 A, with a maximum current of 45 A, a minimum current of 0.15 A, and a starting current of 40 mA. These values help define the operating envelope. The starting current is particularly relevant when monitoring low-load equipment, where a meter must begin registering energy at a small current level. The minimum current and accuracy requirements should still be considered when evaluating very light or intermittent loads.
At only one DIN rail module or 18 mm in width, the meter is especially suited to crowded electrical enclosures. Panel space is increasingly valuable in modern installations because control devices, surge protection, residual-current protection, communication gateways, relays, and circuit breakers may all need to fit in the same enclosure. The narrow body allows designers to add metering without requiring a larger cabinet in many projects.
DIN rail mounting also provides a familiar installation method for electricians. It supports orderly panel construction, simplifies replacement, and enables the meter to be grouped with protective and control equipment. The compact format is practical for both new construction and retrofit projects where available space is limited.
The backlit LCD provides direct access to electrical information without requiring a laptop, handheld instrument, or network connection. A technician can inspect the displayed parameters during installation, commissioning, routine maintenance, and troubleshooting. Backlighting improves readability in darker cabinets, plant rooms, service corridors, and utility compartments.
Local display is important even in a connected system. Communication networks can experience configuration problems, network interruptions, incorrect addresses, or software faults. The LCD gives personnel a direct reference point and helps them compare local readings with data shown by a supervisory platform. This is useful for detecting communication mapping errors or incorrect scaling in a software system.
The meter also provides two pulse outputs. Pulse outputs are a long-established method of transmitting energy increments to a data logger, building controller, display unit, or other compatible device. They can be used for imported and exported energy, depending on the model configuration and application requirements. Pulse-based integration is useful where a simple, isolated energy signal is needed without implementing a complete digital communication network.
The SDM120-M configuration provides two pulse outputs together with RS485 Modbus communication. The product information also identifies related versions that combine pulse outputs with M-Bus or other communication arrangements. This family approach enables users to select the interface that best matches the project. Modbus is widely used in industrial automation and building management, while M-Bus is common in utility and distributed meter-reading applications.
RS485 is well suited to electrical metering because it supports reliable communication over comparatively long cable runs and can connect multiple devices on a bus. The specified maximum transmission distance is up to 1,000 m under appropriate installation conditions. Actual performance depends on cable quality, topology, electromagnetic noise, termination, grounding, baud rate, and the number of connected devices.
The meter supports Modbus RTU with configurable communication addresses from 1 to 247. This allows multiple meters to share a network, with each device identified by its own address. A system designer can install meters at individual apartments, distribution boards, production lines, solar inverters, charging points, or plant areas and collect data through one gateway or controller.
Supported baud rates range from 2,400 bps to 38,400 bps. Parity can be set to none, odd, or even, and stop bits can be set to one or two. These options help the meter integrate with different programmable logic controllers, data concentrators, gateways, energy management systems, and supervisory control platforms. The specified response time is less than 100 milliseconds, supporting responsive polling in many monitoring applications.
Correct RS485 design remains essential. A bus arrangement is generally preferred over a star configuration. Suitable twisted-pair communication cable, correct polarity, appropriate termination, and separation from high-noise power conductors can improve network reliability. Device addresses must be unique, and all connected equipment should use compatible communication settings.
Once configured, the meter can provide values to software for real-time visualization, historical trending, load comparison, alarm generation, energy reporting, and automated control. For example, a building management system can compare energy use across floors, a solar platform can evaluate import and export flow, and an industrial dashboard can identify unusual consumption during non-production periods.
Residential electricity systems are becoming more complex. Homes may contain heat pumps, electric vehicle chargers, battery storage, photovoltaic generation, smart appliances, and home automation equipment. A compact multifunction meter can help monitor individual circuits and understand how these loads interact with the grid.
In an apartment building, one meter can monitor a dedicated apartment supply, common-area circuit, laundry room, ventilation system, or electric heating branch. The local display allows maintenance staff to check readings, while Modbus communication allows data to be collected centrally. This supports consumption comparison, maintenance planning, and more transparent energy management.
For solar photovoltaic systems, bidirectional measurement is particularly relevant. During periods of high generation, electricity may flow from the installation to the grid. At other times, the property may import energy. Measuring both directions helps operators understand self-consumption, exported energy, and the effect of battery or load-management strategies.
In electric vehicle charging applications, the meter can monitor a charging circuit and provide information about voltage, current, power, and accumulated energy. This can support charger diagnostics, usage reporting, cost allocation, and load management. Installers should confirm that the circuit current remains within the direct 45 A capability and that the complete charging installation satisfies all applicable safety requirements.
Small shops, offices, workshops, warehouses, and service facilities often need circuit-level measurement rather than a large power-quality analyzer. A compact DIN rail meter can be installed on lighting panels, HVAC branches, server-room auxiliaries, machinery supplies, refrigeration circuits, or tenant distribution boards.
Submetering is one of the most useful applications. By measuring separate departments, tenants, production areas, or equipment groups, facility managers can identify where energy is being consumed. This supports internal cost allocation and helps organizations establish meaningful energy-saving targets. The information can also reveal that a supposedly efficient area is operating outside its expected schedule.
Industrial users can employ the meter for machine monitoring and preventive maintenance support. A change in current or power factor may indicate a developing mechanical or electrical problem. While the meter is not a replacement for a specialized power-quality recorder or protection relay, its continuous measurement capability can provide an economical first layer of operational visibility.
In temporary installations, the device can be used to monitor site cabins, portable equipment, temporary offices, or construction services. Its small size and direct connection reduce installation effort, while pulse or Modbus outputs make it possible to integrate the readings into a temporary data collection system.
For energy efficiency programs, the meter provides a foundation for measurement and verification. Operators can record a baseline, implement an efficiency measure, and compare subsequent energy use. Because the device measures both instantaneous and cumulative values, it helps distinguish between reduced operating hours, lower power demand, and genuine improvements in equipment efficiency.
The primary advantage over a basic single-function energy meter is the breadth of measurement. A simple meter may show only accumulated active energy, while this multifunction device also provides voltage, current, power, reactive power, apparent power, power factor, frequency, and other operating information. This makes it more useful for diagnosis and system management.
The second advantage is communications flexibility. A basic meter may require manual reading or an external converter. The SDM120-M includes RS485 Modbus RTU, allowing it to communicate directly with many automation and energy management systems. The two pulse outputs provide an additional integration method for installations that use pulse counting.
The third advantage is compactness. At one 18 mm module, the device uses much less panel space than many multifunction meters with larger housings or separate communication modules. Compact dimensions can reduce enclosure size and simplify retrofit work.
The fourth advantage is direct 45 A measurement. Competitors that require external CTs for similar small-load applications may involve higher total installation costs. A direct-connected meter can reduce wiring and configuration requirements while maintaining a professional measurement solution.
The fifth advantage is bidirectional energy measurement. This feature is increasingly important as distributed generation and energy storage become more common. A meter that can recognize energy flow in both directions is more adaptable to modern electrical systems than a device designed only for traditional one-way consumption.
The sixth advantage is the combination of local and remote access. The LCD supports field service, while Modbus supports automation. This dual-access design reduces dependence on a single method of operation and helps different users work with the same meter.
Reliable measurement equipment depends on more than a circuit design. It requires controlled component selection, stable production processes, accurate calibration, firmware development, inspection, environmental testing, and consistent documentation. Eastron’s manufacturing capabilities are supported by a company structure focused specifically on electricity products and energy measurement solutions.
The company develops and produces electricity meters, power analyzers, current sensors, communication modules, and management systems. This product breadth creates useful technical experience across measurement, sensing, communications, embedded software, and system integration. Knowledge gained in one product category can contribute to improvements in another, particularly in signal processing, communications reliability, display control, and energy data management.
Research and development teams in China and the United Kingdom contribute to product development and technology advancement. Cooperation with universities and research institutions further supports the development of new measurement technologies. This combination of internal engineering and external technical cooperation allows the company to respond to changing market needs, including smart metering, distributed energy, electric vehicle charging, and digital building management.
Embedded software is a key part of a modern energy meter. Accurate hardware must be combined with firmware that samples electrical signals, calculates values, records energy direction, controls the display, manages communication, and responds consistently to configuration commands. The company’s experience with software, embedded software, and hardware patents demonstrates a focus on integrated product engineering rather than simple component assembly.
Manufacturing quality also depends on verification. The company operates a professional laboratory capable of performing electromagnetic compatibility, low-voltage directive, accuracy, and environmental tests according to IEC, EN, GB, and UL-related requirements. Such facilities allow products to be evaluated during development and production rather than relying exclusively on external testing at the end of the process.
Accuracy testing verifies that the meter performs within its declared measurement classes. EMC testing examines resistance to electromagnetic disturbance and the device’s own emissions. Environmental testing evaluates performance under conditions such as temperature and humidity changes. Low-voltage and safety-related testing supports the assessment of insulation, dielectric strength, and safe operation. Together, these tests help create a more robust product for real electrical environments.
The company follows the ISO 9001 quality management system. A quality management system supports controlled procedures for design, purchasing, production, inspection, corrective action, documentation, and customer service. It does not remove the need for correct installation, but it provides a structured framework for maintaining consistency across product batches and customer orders.
A dependable meter begins with a clear design specification. Electrical ratings, measurement ranges, accuracy targets, communication parameters, display behavior, environmental conditions, and mechanical requirements must be defined before production. Design reviews can identify risks such as thermal stress, component tolerances, insulation distances, communication interference, or enclosure limitations.
During production, electronic assemblies must be handled using controlled processes. Component placement, solder quality, connector installation, display fitting, terminal assembly, and enclosure closure all affect long-term reliability. Inspection procedures can identify assembly defects before the meter reaches final testing.
Calibration and functional testing are particularly important for measurement devices. Each unit must be evaluated against known electrical conditions to verify voltage, current, power, energy, frequency, and communication behavior. Testing may also confirm display operation, pulse output behavior, address configuration, and response to different load directions.
Traceability improves the ability to investigate quality issues. Production records, test results, component information, and batch data can help manufacturers identify the source of an abnormal result and implement corrective action. For professional users, this contributes to confidence in repeat orders and large multi-site deployments.
The company’s laboratory capability provides an additional advantage during product development. Engineers can test prototypes, compare design revisions, reproduce abnormal conditions, and evaluate improvements. This shortens the feedback loop between engineering and manufacturing and helps maintain control over product performance as designs evolve.
Although the meter is compact, it is installed in a live electrical system and must be treated as a professional electrical component. Installation should be performed by qualified personnel with the supply isolated and verified. The wiring diagram and current direction must be checked before energizing the circuit.
The meter should be installed in a suitable enclosure with adequate protection against accidental contact, excessive moisture, contamination, and mechanical damage. Correct upstream protection must be provided. Conductor sizes, terminal tightening torque, temperature rise, short-circuit conditions, and enclosure ratings should be considered as part of the complete installation design.
Correct phase and neutral identification is essential for a 1P2W meter. Incorrect wiring can lead to invalid readings, reverse energy indications, communication confusion, or unsafe operation. In bidirectional systems, the installer should also verify how imported and exported energy are represented by the selected model and software.
RS485 wiring should be kept away from sources of strong electromagnetic interference where practical. Communication cable shielding, grounding, termination, and routing should follow the requirements of the complete network. If multiple devices are installed, each must have a unique address and matching communication settings.
Pulse outputs should be connected only to compatible receiving equipment. The receiving device must be configured for the correct pulse value, polarity, and energy direction. If pulse data is being used for billing or formal reporting, the entire pulse chain should be tested and documented.
Once connected to an energy management system, the meter can support a range of data-driven functions. Historical records can reveal daily, weekly, and seasonal patterns. Operators can compare working hours with non-working hours and identify energy that remains in use when a facility is expected to be idle.
Power and current trends can help distinguish between a constant base load and variable process demand. A high base load may indicate permanently operating ventilation, refrigeration, pumps, network equipment, or standby machinery. A sudden increase in current may signal a new load, a malfunction, or a change in operating conditions.
Power factor data can help organizations understand the behavior of inductive equipment and evaluate whether correction measures may be appropriate. Reactive and apparent power values provide additional insight into the loading of transformers, cables, and distribution equipment. Any correction strategy must be designed by qualified professionals because inappropriate capacitor installation can create resonance or other system problems.
For photovoltaic systems, comparing imported and exported energy can help calculate self-consumption and identify opportunities to shift loads into periods of high solar generation. For battery systems, the readings can support charge and discharge analysis. For electric vehicle charging, the data can be used to compare charging sessions, monitor peak demand, and design time-based operating strategies.
In multi-tenant properties, submeter data can improve transparency. Each area can be monitored separately, allowing property managers to identify usage differences and provide occupants with more meaningful information. Clear data can encourage behavioral improvements and support fairer allocation of shared energy costs, subject to applicable legal and contractual requirements.
Before ordering the meter, the designer should confirm the electrical system type. This model is intended for a single-phase, two-wire AC system. Projects involving three-phase systems, split-phase systems, higher currents, or specialized instrument transformers may require a different meter model.
The expected load should be checked against the 45 A maximum direct current. Continuous loading, inrush current, ambient temperature, enclosure ventilation, and local wiring requirements should all be evaluated. If the expected current exceeds the direct connection range, a meter designed for current transformers may be more suitable.
The project team should also decide whether it needs Modbus, M-Bus, pulse outputs, or a combination of interfaces. Modbus is typically appropriate where the meter will communicate with a PLC, gateway, building management system, or industrial data platform. Pulse output may be preferred for a simple counter input. M-Bus can be advantageous in utility-oriented meter networks.
Communication parameters should be planned before commissioning. The system designer should establish the address range, baud rate, parity, stop bits, cable type, maximum bus length, termination method, and gateway requirements. A clear addressing schedule is particularly important in large installations.
Accuracy and approval requirements must be reviewed against the intended application. General monitoring, operational analysis, and energy optimization may have different requirements from regulated billing, tenant invoicing, or legal metrology. The exact model designation, certificate, marking, and documentation should be verified before purchase.
Parameter |
Specification or Feature |
Practical Benefit |
System type |
Single-phase AC, 1P2W |
Suitable for individual phase-and-neutral circuits |
|
Nominal voltage |
230 V |
Matches common low-voltage single-phase installations |
Operational voltage |
85–276 V AC |
Provides a broad operating range |
Maximum direct current |
45 A |
Allows direct monitoring without an external CT in many small-load applications |
Module width |
18 mm, one DIN module |
Saves distribution-board space |
Display |
Backlit LCD |
Enables convenient local inspection |
Measurements |
kWh, W, var, VA, V, A, power factor, Hz, demand-related values |
Supports detailed operational analysis |
Energy direction |
Bidirectional measurement |
Supports solar, storage, and grid-interactive applications |
Pulse outputs |
Two outputs for imported and exported energy applications |
Supports simple external data collection |
Communication |
RS485 Modbus RTU |
Enables integration with automation and energy management systems |
Communication address |
1–247 for Modbus |
Permits multi-meter bus networks |
Transmission distance |
Up to 1,000 m under suitable conditions |
Supports distributed installation layouts |
International electrical projects often involve different customer requirements, communication systems, enclosure formats, and compliance expectations. A product platform that offers multiple output configurations is easier to adapt than a meter designed for only one installation style.
The device’s support for recognized measurement and communication standards helps system integrators work within established engineering practices. Modbus RTU is widely understood by automation professionals, while the availability of pulse and M-Bus-oriented versions expands the range of possible applications. The use of a familiar DIN rail format also supports international panel-building methods.
Eastron supplies products to customers in more than 50 countries across Europe, Asia-Pacific, the Americas, the Middle East, and Africa. International experience can help a manufacturer understand the practical differences between markets, including documentation expectations, testing requirements, communication preferences, and after-sales support needs.
Technical support is another important factor in equipment selection. A meter is part of a larger system, and successful deployment may require assistance with wiring, communications, registers, configuration, or troubleshooting. The company provides technical and after-sales teams to support customers during product selection and operation.
Routine maintenance for a digital DIN rail meter should begin with visual inspection. Personnel should check for signs of overheating, discoloration, loose conductors, damaged insulation, moisture, unusual odor, or physical damage. The display should be checked for normal operation, and communication status should be reviewed through the connected software where applicable.
Periodic comparison of displayed values with an independent reference instrument can help identify unusual deviations. Such checks should be carried out under safe conditions and by qualified personnel. If a meter is used in a regulated measurement application, the inspection and verification procedure should follow the applicable legal requirements.
Communication networks should also be maintained. Address conflicts, damaged cables, missing termination, incorrect parity, and unsuitable routing can cause communication failures that may be mistaken for meter faults. Maintaining an updated network schedule and recording configuration parameters can reduce troubleshooting time.
The meter’s compact design and lack of external CT requirements can simplify replacement. If replacement becomes necessary, the same wiring arrangement and communication architecture may be retained, subject to verification of the replacement model and configuration. Before replacement, the circuit must be isolated and made safe.
Electrical meters may operate in distribution cabinets, plant rooms, outdoor-rated enclosures, utility compartments, or equipment skids. Reliability depends on selecting an installation location that is compatible with the device’s environmental specifications. Temperature, humidity, condensation, dust, vibration, and electromagnetic exposure should be considered during project design.
The company’s laboratory testing capability includes environmental evaluation, supporting the development and validation of products for real-world operating conditions. Environmental testing helps engineers understand how the meter behaves when exposed to temperature changes, moisture, and other stresses. The exact environmental limits for a project should always be confirmed from the current technical documentation.
EMC capability is particularly relevant to connected meters. Modern electrical panels may contain variable-frequency drives, switching power supplies, contactors, solar inverters, chargers, and wireless equipment. These devices can create electrical noise. Testing against electromagnetic disturbance helps support reliable measurement and communication when the meter is correctly installed within the system.
Reliability is also influenced by thermal design. Direct current passes through the meter’s current path, so conductor size, terminal tightness, ambient temperature, and continuous load all affect temperature rise. Installers should follow the specified installation practices and avoid placing the device in conditions beyond its rated operating environment.
The meter is designed for RMS measurement on a single-phase AC system with one phase and neutral, commonly identified as 1P2W. It is not a substitute for a three-phase meter or a specialized split-phase meter unless the manufacturer specifically approves that application.
The maximum direct current is 45 A. This allows many residential, commercial, and light-industrial circuits to be measured without an external current transformer. The complete installation must still comply with conductor, protective-device, thermal, and local regulatory requirements.
The nominal voltage is 230 V, and the specified operational voltage range is 85 to 276 V AC. The voltage of the actual installation should be checked before selecting and commissioning the meter.
No. It is a multifunction meter. In addition to active and reactive energy, it can measure voltage, current, active power, reactive power, apparent power, power factor, frequency, and demand-related values.
Yes. The product supports bidirectional measurement, making it suitable for applications where energy may be imported from or exported to the grid, including photovoltaic and energy storage installations.
The SDM120-M uses RS485 with Modbus RTU. The communication address can be configured from 1 to 247, and baud rates from 2,400 bps to 38,400 bps are supported. Parity and stop-bit settings are also configurable.
The specified maximum transmission distance is up to 1,000 m under suitable conditions. Actual distance depends on cable selection, network topology, electromagnetic interference, termination, baud rate, and the number of devices on the bus.
Yes. The product provides two pulse outputs for imported and exported energy applications. Pulse outputs can be connected to compatible data loggers, counters, controllers, or monitoring systems.
Yes. It is designed for DIN rail installation and occupies one 18 mm module. The compact width is useful in distribution boards and control cabinets where panel space is limited.
An external current transformer is not required for loads within the meter’s direct connection range. For circuits exceeding 45 A or applications requiring transformer-based measurement, a different meter configuration may be necessary.
The backlit LCD provides local access to measured values and energy information. It allows installers and maintenance personnel to inspect the circuit without relying exclusively on a communication network or external software.
Yes. Bidirectional measurement, direct current capability, pulse outputs, and RS485 communication make it suitable for many small photovoltaic monitoring applications. The installation must be designed to correctly identify import and export energy and comply with local grid requirements.
It can be used to monitor suitable single-phase charging circuits within the 45 A direct-current limit. The charger, protective devices, cable sizes, residual-current protection, and meter installation must all be selected according to the applicable electrical standards.
The meter includes declared energy accuracy classes and is identified as MID approved in the supplied product information. However, billing suitability depends on the exact model, certificate, markings, installation method, sealing requirements, and laws of the relevant jurisdiction. These details should be verified before use for regulated billing.
The manufacturer develops its own electricity measurement products and maintains engineering capabilities in hardware, embedded software, communications, and systems. It also operates a professional laboratory for EMC, low-voltage, accuracy, and environmental testing and follows an ISO 9001 quality management system.
The installer should verify the system type, nominal voltage, maximum current, wiring diagram, protective devices, conductor sizes, enclosure conditions, communication settings, pulse receiver compatibility, and required approvals. Installation and commissioning should be performed by qualified personnel.
The SDM120-M combines the functions normally associated with a larger multifunction meter with the compactness required for modern distribution boards. Its one-module DIN rail housing, direct 45 A connection, backlit LCD, two pulse outputs, bidirectional energy measurement, and RS485 Modbus RTU communication provide a practical solution for circuit-level energy monitoring.
Compared with a basic kilowatt-hour meter, it provides much more information about how a circuit is operating. Voltage, current, power, power factor, frequency, reactive power, and apparent power readings can support troubleshooting, energy optimization, equipment monitoring, and system planning. Remote communication makes the product suitable for connected buildings, solar installations, charging systems, industrial panels, and submetering networks.
The product is also supported by a manufacturer with experience in electricity meters, power analyzers, current sensors, communication modules, and energy management systems. Its research and development resources, professional testing laboratory, quality management system, international supply experience, and technical support structure strengthen the value of the meter beyond its hardware specification.
For designers seeking a compact single-phase meter with direct connection and digital integration, the device offers an efficient balance of measurement capability, installation simplicity, communication flexibility, and manufacturing support. Correct model selection and professional installation remain essential, but within its intended operating range, it provides a strong foundation for accurate and connected energy management.
IEC 62053-21, Electricity Metering Equipment — Particular Requirements — Static Meters for Active Energy.
IEC 62053-23, Electricity Metering Equipment — Particular Requirements — Static Meters for Reactive Energy.
EN 50470-3:2022, Electricity Metering Equipment — Particular Requirements — Static Meters for Active Energy.
EN 13757, Communication Systems for Meters and Remote Reading of Meters.
ISO 9001, Quality Management Systems — Requirements.
Modbus Application Protocol Specification and Serial Line Implementation Guidance.
Manufacturer product specifications for the SDM120 single-phase multifunction energy meter series.
Manufacturer information concerning electricity measurement products, laboratory testing, quality management, research and development, and technical support.
Your email address will not be published. Required fields are marked *
We develop and produce high performance electricity meters, power analyzers, current sensors, communication modules and management systems.
Address:NO. 52, Dongjin Road, Nanhu, Jiaxing, Zhejiang, China
Copyright @ Eastron Electronic Co., Ltd. All rights reserved